Advanced 3D-Printed Capstan Clamping System for Accurate Uniaxial Tensile Testing of Biological Soft Tissues

Paul Horvath, Franz Gläser, Veronica Antipova, Corina Klug, Alvin C. Lin, Mario Scholze, Niels Hammer*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Featured Application: This study introduces a 3D-printed capstan-based clamping system that enhances uniaxial tensile testing of tendon tissues by reducing stress concentrations and preventing premature failures at the clamping region, resulting in more reliable biomechanical data. Standardized testing methods for the mechanical characterization of biological soft tissues remain underdeveloped in several domains. Existing clamping methods often induce high stress levels in the clamping region, thereby affecting experimental outcomes. This study introduces a 3D-printed clamping system based on the capstan principle. The capstan system was designed and manufactured using 3D printing technology and optimized to minimize the required gripping pressure while maintaining the natural, non-tapered state of specimens. This optimization helps reduce experimental artifacts and prevents premature tissue failure in the clamping region caused by local stress peaks. Usability trials were conducted using human flexor digitorum profundus (FDP) tendons (n = 15). Results showed that 80% of the tendons failed at the midpoint region, indicating the desired load distribution achieved by the clamping mechanism. The elastic moduli, averaging 316.18 ± 86.73 MPa, and failure load properties, averaging 79.25 ± 19.10 MPa, fell within the range of FDP values reported by other researchers, thereby supporting the validity of the capstan design. Capstan clamping offers a promising add-on for biomechanical testing of soft tissues. Further development is necessary to tailor the clamping design to various tissue geometries and to address issues related to tissue moisture regulation, thereby enhancing the reliability and versatility of the clamping system.

Original languageEnglish
Article number11537
JournalApplied Sciences (Switzerland)
Volume14
Issue number24
DOIs
Publication statusPublished - 11 Dec 2024

Keywords

  • 3D printing
  • biomechanical properties
  • capstan principle
  • clamping
  • material slippage
  • soft tissue
  • stress concentration
  • tensile testing

ASJC Scopus subject areas

  • General Materials Science
  • Instrumentation
  • General Engineering
  • Process Chemistry and Technology
  • Computer Science Applications
  • Fluid Flow and Transfer Processes

Fingerprint

Dive into the research topics of 'Advanced 3D-Printed Capstan Clamping System for Accurate Uniaxial Tensile Testing of Biological Soft Tissues'. Together they form a unique fingerprint.

Cite this