Performance evaluation of the FastIC readout ASIC with emphasis on Cherenkov emission in TOF-PET

  • Markus Piller
  • , Antonio M. Castilla
  • , Giulia Terragni
  • , Jerome Alozy
  • , Etiennette Auffray
  • , Rafael Ballabriga
  • , Michael Campbell
  • , Bernd Deutschmann
  • , David Gascon
  • , Alberto Gola
  • , Stefano Merzi
  • , Alicja Michalowska-Forsyth
  • , Michele Penna
  • , Sergio Gómez
  • , Nicolaus Kratochwil*
  • *Korrespondierende/r Autor/-in für diese Arbeit

Publikation: Beitrag in einer FachzeitschriftArtikelBegutachtung

Abstract

Objective. The efficient usage of prompt photons like Cherenkov emission is of great interest for the design of the next generation, cost-effective, and ultra-high-sensitivity time-of-flight positron emission tomography (TOF-PET) scanners. With custom, high power consuming, readout electronics and fast digitization the prospect of sub-300 ps FWHM with PET-sized BGO crystals have been shown. However, these results are not scalable to a full system consisting of thousands of detector elements. Approach. To pave the way toward a full TOF-PET scanner, we examine the performance of the FastIC ASIC with Cherenkov-emitting scintillators (BGO), together with one of the most recent SiPM detector developments based on metal trenching from FBK. The FastIC is a highly configurable ASIC with 8 input channels, a power consumption of 12 mW ch−1 and excellent linearity on the energy measurement. To put the timing performance of the FastIC into perspective, comparison measurements with high-power consuming readout electronics are performed. Main results. We achieve a best CTR FWHM of 330 ps for 2 × 2 × 3 mm3 and 490 ps for 2 × 2 × 20 mm3 BGO crystals with the FastIC. In addition, using 20 mm long LSO:Ce:Ca crystals, CTR values of 129 ps FWHM have been measured with the FastIC, only slightly worse to the state-of-the-art of 95 ps obtained with discrete HF electronics. Significance. For the first time, the timing capability of BGO with a scalable ASIC has been evaluated. The findings underscore the potential of the FastIC ASIC in the development of cost-effective TOF-PET scanners with excellent timing characteristics.

Originalspracheenglisch
Aufsatznummer115014
Fachzeitschrift Physics in Medicine and Biology
Jahrgang69
Ausgabenummer11
DOIs
PublikationsstatusVeröffentlicht - 7 Juni 2024

ASJC Scopus subject areas

  • Radiologie- und Ultraschalltechnik
  • Radiologie, Nuklearmedizin und Bildgebung

Fingerprint

Untersuchen Sie die Forschungsthemen von „Performance evaluation of the FastIC readout ASIC with emphasis on Cherenkov emission in TOF-PET“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren